Blue Color Ground water Level Meter 30m-500m

LOADING IMAGES
  • The steel ruler water level gauge provides the most accurate way to measure the water level, it can be used to measure the water level inside wells, boreholes and the water level pipes.

    Description

    Accurate Measurement Steel Ruler Water Level Gauge

     

     

    Parameters

     

    Specification 30 50 100 150 200 300 500
    Measurement dept(m) 0~30 0~50 0~100 0~150 0~200 0~300 0~500
    Minimum reading(mm) 1.0
    Repetitive reading(mm) ±2.0
    Operating voltage (V) DC=9


    Instruction
    During measurement, after the coil has been rotated, press the power, and put the probe into the water pipe, then hold the steel ruler cable, let the probe moves down slowly.
     
    The sounder will gives a continuous beep when the contact point touches the water surface, then can read the depth of the steel ruler at the pipe mouth, that is the distance from the underwater level to the pipe mouth .


    Specification 
     
    The steel ruler water level gauge provides the most accurate way to measure the water level, it can be used to measure the water level inside wells, boreholes and the water level pipes, it’s very suitable for the underground water level observation in hydroelectric engineering and manual inspection of the earth and rock dam body saturation line.
     
    The instrument can be used during construction, and also long term engineering safety monitoring, it complies with the earth dam safety monitoring technical specifications. 


    Maintenance
    Due to the battery capacity, please turn off immediately after the measurement is completed! Remove the battery cover and replace the battery (9V battery, multimeter battery).
     
    Keep the probe and the steel ruler cable clean after use, and put the steel ruler cable neatly around the reel, and be placed in the cabinet.
     
    Don’t bend the measuring cable , especially when it is close to the head, to avoid the cable to be damaged.
     
    Put the probe gently to avoid severe vibration. If the probe got any problem, please send back to our factory.
     