Service Line:+86-13810682636

Products

Pile Test

Borehole Camera

Cement Test

Concrete Test

NDT Equipments

Geophysical Instruments

Petroleum Equipments

Soil Test

FBG

XRY-1C Automatical Oxygen Bomb Calorimeter

LOADING IMAGES
  • Standard:ASTM D240;GB/T213,GB/T384,JJG672
    This instrument is a computer-controlled, auto. and intelligent instrument that can automatically complete the heating value test of flammable substances. The semiconductor refrigeration water circulation system

    Description

    Summary

      The instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb Calorimeter, as well as Shanghai enterprise standard Q/YXYY 10 XRY Series Oxygen Bomb Calorimeter.

    I. Main technical features
    1. Adopting semiconductor refrigeration to decide the refrigerating capacity according to the calorific value,the instrument can automatically adjust water temperature and keep water in a relative constant temperature range,realize the continuously and long time test requirement,and make sure the test result is correct.
    2. Using USB port,convenient to connect.One computer can control many sets of Oxygen Bomb Calorimeter.
    3. With a electronic measuring cup itself,no need to weigh the water by manual,it can measure the water volume automatically,the repetitive error<0.4g
    4. Automatically detecting the resistance of ignition filament,automatically checking the installing condition of ignition filament before test.
    5. Standard pipeline design,vastly shortening the pipeline,and more reasonable pipeline design to ensure more precision of test results.
    6. Adopting professional discharge water ports,more convenient and fast when the  instrument drains away water or change the water.
    7. The electronic balance with communication function to share the data by the internet.

    II. Main technical specifications
    1. Measuring temperature range: 5℃~40℃
    2. Temperature resolution: 0.0001℃
    3. RSD(Relative standard deviation): ≤0.1%
    4. Test period: ≤13mins
    5. Measuring range: 5MJ/kg~40MJ/kg
    6. Accuracy:Better than GB/T213-2008 The determination method of coal calorific value
    7. Pressure endurance of oxygen bomb: 20 MPa
    8. Relative humidity: ≤85%
    9. Power supply: AC 220V±10V, 50 Hz
    10. Total power consumption: ≤0.2kW
    11. Outline dimension: 540mm×420mm×420mm(L×W×H)
    12. Net weight: 55kg