FBG

2430A Automatic Freezing Point Tester

LOADING IMAGES
  • Standard:ASTM D1177,D2386
    The vacuum Dewar cold tank can be used to perform two samples in parallel. Imported compressor cascade refrigeration, cold bath temp. can reach -80 ℃. Freezing point range: 2 ~-54 ℃, cold bath temp. measurement: -100~ 50 ℃, samp

    Description

    Summary
    The instrument is designed and made as per the Industrial Standard of People’s Republic of China GB/T 2430 ,SH/T0090-1991(2000), ASTM D1177,D2386 Standard Test Method for Freezing Point of Engine Coolant. It can be used to test freezing point of engine coolants and condensation liquids.

     

    I.Main technical features
    1.The cold bath is made of stainless steel,double glass observating window,with the advanced temperature control technology,the lowest tempeature degree is -70℃,the temperature accuracy is ±0.5℃,fitting standard GB/T 2430,SH/T 0090 and ASTM D1177,D2386  for the freezing point test requirement.
    2.Automatically judge the freezing point temperature.
    3.According to the different configuration,it can be used to test the freezing point etc.indexes of jet fuel,engine coolant and its concentrated solution,it's a multipurpose freezing point tester.
    4.It's the floor stand structure,the work table-board is made of stainless steel,concise design,nice appearance,convenient usage,fully furnished.              
    The maximal characteristic:Unit as one to measure jet fuel freezing point and engine coolant freezing point;automatically stirring sample and judging the freezing point temperature,fast cooling,high precision temperature control,full spraying plastic case,wear well.


    II. Main technical specifications
    1.Power supply: AC 220 V±10%, 50 Hz;
    2.Working bath: stainless steel,double vacuum glass observing window.
    3.Freezing point range:-54℃~2℃.
    4.Cold bath measurement temperature: -70℃~20℃
    5.Temperature controlling accuracy: ±0.5℃                                               
    6.Bath liquids stirring: electric stirring.the power is 6W,1200r/min.
    7.Refrigerator system:imported refrigerator compressor
    8.Sample stirring: mechanical stirring is 0~120r/min,continuously adjustable              
    9.Ambient temperature: ≤30℃.
    10.Relative humidity: ≤85%
    11.Maximum power consumption: 2000 W
    12.Dimension: 560㎜×550㎜×810㎜