NDT of Concrete Structures or Other Non-ferromagnetic Media for Integrated Floor Thickness Gauge
Product description:
SAM Integrated Floor Thickness Gauge is mainly used for non-destructive testing of concrete structures or other non-ferromagnetic media thickness measurements, such as: measurement of non-ferromagnetic thickness measurement of cast-in-situ slabs, walls, beams, columns, wood and ceramics; The unique design method of combining the probe and the main unit is as simple as testing the corresponding surface of the transmitting probe (floor, etc.) and measuring the non-ferromagnetic thickness value.
According to the standard:
"Construction Quality Acceptance Specification for Concrete Structure Engineering"..........................................GB 50204-2002
"Rebar protective layer thickness measuring instrument, floor thickness measuring instrument measurement and calibration specification"..................JJF1224-2009
Features:
Quick real-time positioning, real-time display of the position of the transmitting probe, and rapid positioning through direction indication;
Real-time display of measured values, automatic locking of true thickness;
2.8-inch high-resolution color LCD screen, the detection data can be clearly seen in any situation indoors and outdoors;
With one-hand grip and operation design, it is easy to operate and quickly find the position of the transmitting probe.
Using USB mode data transmission, the stored data can be quickly uploaded to the computer through the USB cable;
Using data storage mode, data storage, viewing, deletion and other functions, can store more than 200,000 points of measurement data;
It adopts integrated design of main unit and receiving probe, which is small in size, light in weight and easy to carry;
Four wheel alignment is adopted, and the outer wheel is equipped with high-strength wear-resistant tires to facilitate the protection of instrument wear;
Equipped with a professionally designed standard calibration test block;
The standard telescopic rod features a professional and unique dual 90 degree universal joint that can be adjusted within 360°.
Technical Parameters:
Model |
SY |
||
Test thickness range (mm) |
20 to 999 |
||
Measurement mode |
Ordinary thickness detection |
||
Compensated thickness detection |
|||
Test accuracy (mm) |
20-200 |
±1 |
|
201-400 |
±2 |
||
401-600 |
±3 |
||
601999 |
≥±6 |
||
Data storage capacity |
200000 measuring point |
||
Display resolution |
320*240 |
||
Data transmission mode |
USB |
||
Power supply time |
Host |
Not less than 26h |
|
Probe |
Not less than 64h |
||
Host |
Volume (mm) |
219×92×106 |
|
Weight (g) |
700 |
||
Transmitting probe |
Volume (mm) |
Ø100×110 |
|
Weight (g) |
500 |
||
Telescopic rod |
Volume (mm) |
Ø28×470(1.5m)+0.5m |
|
Weight (g) |
400 |