LOADING IMAGES
  • The instrument adopts desktop, all-in-one and double inner crucible structure. Both of inner and outer crucible adopt stainless materials. Inner crucible has been specially processed. The smooth finish corresponds with the test requirements.

    Description

    WNE-1B Engler Viscometer

    Summary

    This instrument is designed and made as per national standard GB/T266 Petroleum Products- Determination of Engler Viscosity, T0622 Bitumen Engler Viscosity Determination (Engler viscometer method) in national industrial standard JTG052 Standard Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering and Shanghai enterprise standard Q/YXYY11 WNE-1 Engler Viscometer. It is suitable to determine the rate of time(seconds) of liquid flow out from Engler viscometer and time(seconds) of distilled water flow out at 20℃ under certain temperature and cubage. This rate is the Engler viscosity. Unit is Engler degree.

     

    I. Main technical features

    1. The instrument adopts desktop, all-in-one and double inner crucible structure. Both of inner and outer crucible adopt stainless materials. Inner crucible has been specially processed. The smooth finish corresponds with the test requirements.

    2. The flow out time adopts digital display. Can do parallel determination for 2 samples at the same time. Easy to use and efficiency is high.

    3. The temperature controller adopts digital display temperature controller with P,I,D position regulatory function. Easy to set the parameters and temperature controlling precision is high.

        

    II. Main technical specifications

    Power supply AC(220±10%)V, 50Hz
    Standard water value (51±1) s
    Testing temperature (0~100)
    Temperature control accuracy ±0.1℃
    Engler viscosity thermometer correspond with GB/T 514
    Specification of measuring flask (200±0.2) ml
    Inner crucible stainless steel material
    Timing Max 999.9s
    Timing mode LED electronic timing 
    Heating power 700W
    Ambient temperature (-10~+40)
    Relative humidity ≤85%
    Dimension 430mm×410mm×620mm
    Maximum power consumption 800W

     

     