Service Line:+86-13810682636

Products

Pile Test

Borehole Camera

Cement Test

Concrete Test

NDT Equipments

Geophysical Instruments

Petroleum Equipments

Soil Test

FBG

Concrete Rebar locator

LOADING IMAGES
  • JGJ/T152-2008 Technical specification for test of reinforcing steel bar in concrete

    Description


    SYR51+ Rebar Location System
    Purpose
    SYR51+ Rebar Location system is used to test rebar diameter, distribution, coating thickness in concrete.
    Specification
    <Technical specification for test of reinforcing steel bar in concrete> JGJ/T152-2008
    Performance
    Longer service life of the Connector Clip: The instrument has long service life because of using Lemo Connector Clip which comes from Swiss and uses for aircraft industry.
    Good quality of signal cable: The signal cable has long service life because of its flexible and substance.
    High precision and stability: The instrument can locate the steel-bar accurately and quickly.
    Longer service life of the sensor: Improve the service life by paste abrasion resistance allowance bottom of the sensor
    Single sensor: No-change sensor in test, switching between high and low test range can assure the precision of test data and the test depth.
    Display test information real-time: Display the test data directly to avoid man-made errors.
    Grid and section scan mode: Instrument can display steel bar distribution and scan steel bar without concrete boundary limited.
    Three-wheel steel-bar scan system: The system can assure scan path along line and the precision of test data.
    Powerful Windows data process and analysis software: Software can display analysis result by diagram. Test data can be export to word or Excel easily.
     
    Technical Data
    Applicable rebar diameter 6mm~50mm
    Tested range of concrete coating thickness Low range: 6mm~90mm; High range: 7mm~190mm
    Permissible error   Low range High range
    ±1 6~59 7~79
    ±2 60~69 80~119
    ±4 70~90 120~190
    Tested range of rebar diameter 6mm~50mm
    Permissible error of rebar diameter test ±1 grade
    Applicable environmental Temperature: -10℃~+40℃; Dampness: <90%RH
    EMI: no Strong electromagnetic field
    Power supply 6 dry cells, work more than 30 times
     
     