Test force range | 50kN ~ 50MN | ||
Maximum test force | 1000kN (1MN) | ||
Test force measurement range | 2%-100% F.S | ||
Force value error (in, return) | Within the range of 2%-10%F.S, the test data is better than ±0.03%; Test data is better than ±0.01% in the range of 10%-100%F.S |
||
Force value repeatability | Within the range of 2%-10%F.S, the test data is better than 0.03%; Within the range of 10%-100% F.S; test data is better than 0.01% |
||
Initial load discrimination | 10% FS, better than 0.01% | ||
Load volatility | Within the range of 2%-10% F.S, the test data is better than 0.01%; Test data in the range of 10%-100% F.S is better than 0.003% |
||
Azimuth error |
Within the range of 2%-10%F.S, the test data is better than 0.06%; Test data is better than 0.02% in the range of 10%-100%F.S |
||
Test space (length X width X height) | 1MN (600 X 600 X 800mm) |